Product line 08 / 12 · Plug-in Units
Modular electronics deserve modular mechanics: shielded frame-type plug-in units that slide into a subrack and seal it.
Frame-type plug-in units carry individual electronic modules inside a 19″ subrack. Each unit is a self-supporting aluminium frame with its own front panel, so modules can be swapped without opening the cabinet. Built to IEC 60297-3-102 / -103 and IEEE 1101.10, the front panels are shieldable with textile EMC gaskets, and the inserter/extractor handles (type IEL / IET) deliver insertion and extraction forces up to 700 N per pair — heavy-duty versions up to 1500 N — while mechanical keying prevents a module from being inserted into the wrong slot. Microswitches for slot-status signalling and label strips for slot identification are part of the accessory set.
| Heights | 3U / 6U |
| Widths | 4HP – 84HP |
| Depth | to match subrack and board depth |
| Frame | aluminium extrusion, conductive finish |
| Standards | IEC 60297-3-102 / -103 · IEEE 1101.10 |
| EMC | shieldable front panels, textile EMC gasket |
| Handles | IEL / IET inserter-extractor to 700 N per pair · XL to 1500 N |
| Options | coding keys, microswitch, label strips, screw sets |
Same interface dimensions as the nVent SCHROFF equivalents — our own tooling, material and finish.
Every model has its own page with specifications and RFQ. Use your browser search (Ctrl/Cmd+F) on this page, or send us the number and we will quote it.
A plug-in unit is a mechanical envelope for a PCB. The single decision that constrains everything else is the pair of numbers: how deep the board is, and how deep the rails in the subrack are.
| Rail body depth | Board depth that fits | Usual application |
|---|---|---|
| 160 mm | up to about 100 mm | compact I/O cards, 3 U control boards |
| 220 mm | about 160 mm | the common 3 U / 6 U industrial card |
| 280 mm | about 220-233 mm | 6 U compute and telecom boards, rear transition modules |
A frame-type plug-in unit is not just a box: it adds a front panel, top and bottom covers, two side extrusions, a handle and, where specified, EMC gaskets. Each of those takes space inside the rail depth. A 220 mm rail with a 160 mm board leaves roughly 40 mm for the connector, the panel thickness and the handle mechanism — which is why the same board can be a standard build in one subrack and a custom panel in another.
The handle is a lever, and the leverage is what lets a 96-pin connector seat without stressing the board. Below roughly 60 N of insertion force a simple handle is fine; above that, specify an extractor/injector style and make sure the panel cut-out and the subrack rail both accept it. Quote the connector type and pin count with the enquiry — it is the fastest way to get the right handle on the first quote.
Where this product line is typically used.
Parts that usually go together with Frame-Type Plug-in Units.
Related categories
Up to 700 N per pair with IEL / IET handles to IEEE 1101.10 and IEC 60297-3-102. Heavy-duty versions reach 1500 N. Units are 3U or 6U, 4 HP-84 HP, with depths matched to the subrack and board.
Mechanical keying and coding. Label strips identify the slot, and microswitches can signal slot status. Front panels are shieldable with textile EMC gaskets, and each unit is a self-supporting aluminium frame with its own panel, so a module can be swapped without opening the cabinet.
Made in our own plants — chassis and precision parts from Kunshan, cabinets and surface finishing from Hefei: CNC punching, press braking, CNC machining, assembly, inspection and export packing in-house.
Kunshan plant →Hefei plant →Cross-referencing against major international 19″ system part numbers is our daily routine — we quote within 24 hours for standard items.