Kunshan Plant · Jiangsu  |  Hefei Plant · Anhui, China [email protected]  |  WhatsApp +86 132 6227 6239
C-BOX Electronic Technology Request a Quote
Home  ›  Products  ›  Subracks & 19″ Chassis  ›  24563-193

Subracks & 19″ Chassis · 19" Subracks & Cases

EuropacPRO 19" Subrack Kit for DIN Connector, Retrofit Shielding, 3 U, 295 mm

Non-shielded subrack for Din Connector mounting EN 60603-2 (DIN 41612).

Catalog#: 24563-193 · 24563193

Download Catalog (PDF) Download Spec Sheet (PDF) Dimension & Hole Layout (PDF) Request a Sample
Lead time
7 days
standard items, ex-works China
MOQ
1 pc
one unit is fine — mix sizes freely
Samples
On request
we ship a sample against your PO or courier account
C-BOX EuropacPRO 19" Subrack Kit for DIN Connector, Retrofit Shielding, 3 U, 295 mm, catalog number 24563-193

Features

  • Aluminum construction
  • Anodized; Passivated finish
  • 84HP rack width
  • 3U rack height
  • Subrack/Chassis
  • Complies with IEC 60297-3-103

Specifications

Catalog Number24563-193
Rack Width84HP
Rack Height3U
MaterialAluminum
FinishAnodized; Passivated
Product TypeSubrack/Chassis
Complies WithIEC 60297-3-103
Static Load11kg
Package Quantity1
Depth295mm
For MountingDIN Connector
Board Depth160mm; 220mm; 280mm
Gasket TypeStainless Steel EMC (retrofittable)
Handle IncludedNo
MountingRack
EMC ShieldingNo
Net Weight1.23kg

Item(s) Delivered

Same series · catalog number comparison

Codes that start with 24563 share the same interface and mounting geometry; height, width, depth or pack quantity is what changes. Pick the row that matches your BOM — if you are replacing another brand’s number, tell us the code and we will confirm the match.

Catalog no.DepthPack qtyDescription
24563-163295 mm1EuropacPRO 19" Subrack Kit for Backplane, Heavy, Retrofit Shielding, 3 U, 295 mm
24563-164355 mm1EuropacPRO 19" Subrack Kit for Backplane, Heavy, Retrofit Shielding, 3 U, 355 mm
24563-172235 mm1EuropacPRO 19" Subrack Kit for Backplane, Heavy, Shielded, 3 U, 235 mm
24563-173295 mm1EuropacPRO 19" Subrack Kit for Backplane, Heavy, Shielded, 3 U, 295 mm
24563-174355 mm1EuropacPRO 19" Subrack Kit for Backplane, Heavy, Shielded, 3 U, 355 mm
24563-191175 mm1EuropacPRO 19" Subrack Kit for DIN Connector, Retrofit Shielding, 3 U, 175 mm
24563-192235 mm1EuropacPRO 19" Subrack Kit for DIN Connector, Retrofit Shielding, 3 U, 235 mm
24563-193 ← this page295 mm1EuropacPRO 19" Subrack Kit for DIN Connector, Retrofit Shielding, 3 U, 295 mm
24563-194355 mm1EuropacPRO 19" Subrack Kit for DIN Connector, Retrofit Shielding, 3 U, 355 mm
24563-255175 mm2EuropacPRO Advanced EMC Side Panel Cover, 3U, 175 mm
24563-256235 mm2EuropacPRO Advanced EMC Side Panel Cover, 3U, 235 mm
24563-257275 mm2EuropacPRO Advanced EMC Side Panel Cover, 3U, 275 mm
24563-258277.75 mm2EuropacPRO Advanced EMC Side Panel Cover, 3U, 277.75 mm
24563-259295 mm2EuropacPRO Advanced EMC Side Panel Cover, 3U, 295 mm

Showing 14 of 167 codes in the 24563 series — see the full series →

Lead time 7 days for standard items · MOQ 1 pc · ask for a quote or a sample

Questions specific to 24563-193

Answers below use this catalog number's own figures from the specification table above.

295 mm deep — which board depth does that take?

This frame is 295 mm deep. With the rails on their 15 mm grid this frame takes boards from 160 mm to 280 mm, depending on where the rails sit. If a rear transition module is planned, allow another 80 mm behind the board, because the rear side of the connector still needs clearance.

Does it take DIN connectors or a backplane?

DIN connector mount: the boards plug into IEC 60603-2 / DIN 41612 connectors carried in the rails, so the connector is part of the mechanics. If a rear PCB is planned instead, this is the wrong variant — the backplane-mount version of the same series has the rail profile for an insulating strip.

Is EMC shielding available for this variant?

No. This variant ships unshielded and is not prepared for a gasket, so if a shielding figure is in your specification, move up to the shielded variant of the same series (stainless-steel or textile gasket) instead of trying to retrofit this frame.

11 kg static load — what does that cover?

The rating covers the complete assembly: frame, rails, backplane and the plug-in units, with the frame supported at both 19″ brackets. The same series has heavier and lighter variants — the comparison table above lists them — so a heavier payload is a variant change, not a reinforcement. Weigh the loaded assembly rather than the bare enclosure before you compare this figure with another supplier's.

Related 19" Subracks & Cases

Catalog#: 21500-067
EuropacPRO 19" Subrack Kit for Railway, Retrofit Shielding, SNCF, 3 U, 36 HP, 320 mm
Catalog#: 21500-068
EuropacPRO 19" Subrack Kit for Railway, Shielded, SNCF, 3 U, 36 HP, 320 mm
Catalog#: 21500-070
EuropacPRO 19" Subrack Kit for Railway, Retrofit Shielding, SNCF, 6 U, 36 HP, 320 mm
Catalog#: 21500-071
EuropacPRO 19" Subrack Kit for Railway, Shielded, SNCF, 6 U, 36 HP, 320 mm
Catalog#: 24563-107
EuropacPRO 19" Subrack Kit for Backplane, Wall Mount, Unshielded, 3 U, 205 mm
Catalog#: 24563-108
EuropacPRO 19" Subrack Kit for Backplane, Wall Mount, Unshielded, With Rear Hood, 3 U, 205 mm
Catalog#: 24563-109
EuropacPRO 19" Subrack Kit for DIN Connector, Wall Mount, Unshielded, 3 U, 205 mm
Catalog#: 24563-110
EuropacPRO 19" Subrack Kit for DIN Connector, Wall Mount, Unshielded, With Rear Hood, 3 U, 205 mm

Compatibility with nVent SCHROFF 24563-193

This C-BOX part is compatible with nVent SCHROFF 24563-193 — same interface dimensions, our own tooling, material and finish. It is also a direct replacement for nVent SCHROFF 24563-193: a drop-in alternative for existing installations, no rework required.

Cross-reference: nVent SCHROFF 24563-193, nVent 24563-193, SCHROFF 24563-193 — matching C-BOX catalog number 24563-193. Same hole pattern, same panel cut-out, same thread.

Cross-referencing a different part number? Send it to us and we will match the equivalent C-BOX part, with drawing and lead time.

Send us your drawing or part number

Need 24563-193 or a compatible custom version? Send an RFQ — engineering response within one business day.

Request a Quote